电场探头?HI-6105电场探头
ETS-Lindgren的HI-6105电场探头在100 kHz至6 GHz的频率响应下工作。
ETS-Lindgren的激光驱动HI-6105电场探头体现了各向同性传感器设计和低噪声,小型化电子设备的新创新。HI-6105设计为单量程读数,可在整个动态范围内连续读取数据。每个轴(X,Y和Z)的数据值可以单独读取或求和。光纤信号和电源线将Model HI-6105 RF现场探头连接到EMCenter,或者通过HI-6113激光数据接口和ProbeView 激光软件直接连接到PC USB端口。
除了作为系统级平台的功能外,EMCenter 模块化射频平台和EMSense 接口卡还可以与HI-6000系列现场探头一起用作现场监控器。
HI-6113激光数据接口为HI-6105电场探头提供激光功率和通信。使用ProbeView for Laser Probes软件,与PC的USB连接可以快速轻松地收集数据。
ELECTRIC FIELD PROBES HI-6105 Electric Field Probe
?ETS-Lindgren’s?HI-6105 Electric Field Probe operates at a Frequency Response of?100 kHz to 6 GHz
ETS-Lindgren’s?laser-powered HI-6105 Electric Field Probe embodies the latest innovations in isotropic sensor design and low noise, miniaturized electronics. Designed to be single range reading, the HI-6105 can read data continuously over the entire dynamic range. Data values for each axis (X, Y, and Z) can be read individually or summed.?Fiber optic signal and power lines link the Model HI-6105 RF?field probe to either the?EMCenter, or as a direct connect to a PC USB port with the HI-6113 Laser Data Interface and ProbeView? Laser Software.
The EMCenter? Modular RF Platform along with the EMSense? interface card can be used with the HI-6000 series field probes as a Field Monitor in addition to its capability as a system level platform.???
The HI-6113 Laser Data Interface provides the laser power and communications for the HI-6105 Electric Field Probe. A USB connection to the PC allows for quick and easy data collection, using ProbeView?for Laser Probes software.
主要特点
- 激光供电 – 允许扩展测试
- 频率响应:?
- 100 kHz至6 GHz
- 动态范围0.5 V / m至800 V / m(单量程)?
- 提供单个和总和轴值
- A2LA认可的校准报告
- 适用于MIL标准规格:
- ?MIL-STD 461F辐射敏感性(RS)?
- 适用于汽车规格:
- SAE J1113??27
- GMW 3091/?3097/?3103
- 福特FMC 1278
- 适用于商业规格:EN / IEC 61000-4-3?辐射抗扰度
- 使用大多数第三方免疫软件运行
对于高场和高频要求,建议使用HI-6×53型
- 适用于汽车规格:
产品规格
电气规格
检测:?各向同性(X,Y和Z轴读数)
- 500 kHz至2 GHz +1.0,-2.5 dB
- 2 GHz至5.5 GHz +3.5,-4.5 dB
- 5.5 GHz至6 GHz +2.0,6.0 dB
物理规格
物理接口:
- 双工光纤(62.5微米多模)
- 用于激光电缆的FC连接器,整体1m光缆
- ST变送器电缆连接器,1米光缆
工作范围:??10°C至40°C(50°F至104°F);?5至95%相对湿度无凝结
其他规格
- 手册
- 探针组装
- A2LA可追踪校准报告
- 10米光缆
- 隔板连接器(2)
- 携带箱
- 纤维清洁套件和棉签
Key Features
- Laser Powered -Permits Extended Testing
- Frequency Response:?
- 100 kHz to?6 GHz
- Dynamic Range 0.5?V/m to 800 V/m (Single Range)?
- Provides Individual and Summed Axis Values
- A2LA Accredited Calibration Report
- Suitable for MIL Standard Specs:
- ?MIL-STD 461F Radiated Susceptibility (RS)?
- Suitable for Automotive Specs:
- SAE J1113?27
- GMW 3091/3097/3103
- FORD FMC 1278
- Suitable for Commercial Specs:?EN/IEC 61000-4-3 Radiated Immunities
- Operates with Most 3rd Party Immunity Software
For High Field?and High Frequency Requirements the Model HI-6×53 is Recommended
Specifications
Electrical Specifications
Detection: Isotropic (X, Y and Z Axis Readings)
- 500 kHz to 2 GHz +1.0,?-2.5 dB
- 2 GHz?to 5.5 GHz +3.5, -4.5 dB
- 5.5 GHz?to 6 GHz +2.0, -6.0 dB
Physical Specifications
Physical Interface:
- Duplex Optical Fiber (62.5 Micron Multimode)
- FC Connectors for Laser Cable, Integral 1m Optical Cable
- ST Connector for Transmitter Cable, Integral 1m Optical Cable
Operating Range:?10°C to 40°C (50° F to 104° F); 5 to?95% Relative Humidity Non-condensing
Other Specifications
- Manual
- Probe Assembly
- A2LA Traceable Calibration Report
- 10m Optical Cable
- Bulkhead Connector (2)
- Carrying Case
- Fiber Cleaning Kit and Swabs

Graphs for Uploading

Graphs for Uploading

Graphs for Uploading